Eaton STS232050U152 TVS Diode 5 V 350 W
Eaton STS232050U152 TVS Diode 5 V 350 W

Eaton STS232050U152 TVS Diode 5 V 350 W

Share
STS232050U152: 5 V standoff TVS diode array, 2-channel, 150 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232050U152 TVS Diode 5 V 350 W

    STS232050U152 at a glance: TVS diode array ESD suppressor, 5 V standoff, 16.7 V clamp, 2 channels, 150 pF, 350 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS232050U152
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A9.8 V
    Clamping voltage at 18 A16.7 V
    Junction capacitance at 1 MHz, per line150 pF typ / 180 pF max
    Channels2
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-8 kV contact / +/-15 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11148

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11148. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    At 18 A the clamp sits at 16.7 V, or 3.34 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    150 pF per line is 1.1 ohms of reactance at 1 GHz and 10.6 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Placement in the Circuit

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message