Eaton STS232120U901 ESD Suppressor 12 V 90 pF
Eaton STS232120U901 ESD Suppressor 12 V 90 pF

Eaton STS232120U901 ESD Suppressor 12 V 90 pF

Share
STS232120U901: 12 V standoff TVS diode array, 2-channel, 90 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232120U901 ESD Suppressor 12 V 90 pF

    STS232120U901 at a glance: TVS diode array ESD suppressor, 12 V standoff, 26 V clamp, 2 channels, 90 pF, 500 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS232120U901
    Standoff voltage (VRWM)12 V
    Breakdown voltage (min / typ / max)13 V
    Leakage current at VRWM0.15 uA max
    Peak pulse power, 8/20 us, per line500 W
    Clamping voltage at 1 A18 V
    Clamping voltage at 20 A26 V
    Junction capacitance at 1 MHz, per line90 pF typ
    Channels2
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11156

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11156. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    At 20 A the clamp sits at 26 V, or 2.17 times the 12 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 500 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    90 pF per line is 1.8 ohms of reactance at 1 GHz and 17.7 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 12 V the part draws at most 0.15 uA, which is 1.8 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Layout and Placement

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.