Eaton STS232150B251 ESD Suppressor 15 V 25 pF
Eaton STS232150B251 ESD Suppressor 15 V 25 pF

Eaton STS232150B251 ESD Suppressor 15 V 25 pF

Share
STS232150B251: 15 V standoff TVS diode array, 2-channel, 25 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232150B251 ESD Suppressor 15 V 25 pF

    STS232150B251 at a glance: TVS diode array ESD suppressor, 15 V standoff, 35 V clamp, 2 channels, 25 pF, 350 W.

    Specification Table

    ParameterValue
    Orderable part numberSTS232150B251
    Standoff voltage (VRWM)15 V
    Breakdown voltage (min / typ / max)16.7 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A24 V
    Clamping voltage at 10 A35 V
    Junction capacitance at 1 MHz, per line25 pF typ
    Channels2
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11147

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11147. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 10 A the clamp sits at 35 V, or 2.33 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    25 pF per line is 6.4 ohms of reactance at 1 GHz and 63.7 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Board Layout

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • The capacitance figure is at zero bias. At the working voltage the junction depletes and the value falls, so the loading on a live bus is lower than the table suggests.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.