Eaton STS232150U451 TVS Diode 15 V 350 W
Eaton STS232150U451 TVS Diode 15 V 350 W

Eaton STS232150U451 TVS Diode 15 V 350 W

Share
STS232150U451: 15 V standoff TVS diode array, 2-channel, 45 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232150U451 TVS Diode 15 V 350 W

    STS232150U451 at a glance: TVS diode array ESD suppressor, 15 V standoff, 35 V clamp, 2 channels, 45 pF, 350 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS232150U451
    Standoff voltage (VRWM)15 V
    Breakdown voltage (min / typ / max)16.7 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A24 V
    Clamping voltage at 10 A35 V
    Junction capacitance at 1 MHz, per line45 pF typ
    Channels2
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-8 kV contact / +/-15 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11148

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11148. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    At 10 A the clamp sits at 35 V, or 2.33 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    45 pF per line is 3.5 ohms of reactance at 1 GHz and 35.4 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    Placement in the Circuit

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.