Eaton STS232240B151 ESD Suppressor 24 V 15 pF
Eaton STS232240B151 ESD Suppressor 24 V 15 pF

Eaton STS232240B151 ESD Suppressor 24 V 15 pF

Share
STS232240B151: 24 V standoff TVS diode array, 2-channel, 15 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232240B151 ESD Suppressor 24 V 15 pF

    STS232240B151 at a glance: TVS diode array ESD suppressor, 24 V standoff, 60 V clamp, 2 channels, 15 pF, 350 W.

    Specification Table

    ParameterValue
    Orderable part numberSTS232240B151
    Standoff voltage (VRWM)24 V
    Breakdown voltage (min / typ / max)26.7 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A43 V
    Clamping voltage at 6 A60 V
    Junction capacitance at 1 MHz, per line15 pF typ
    Channels2
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11147

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11147. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    At 6 A the clamp sits at 60 V, or 2.50 times the 24 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    15 pF per line is 10.6 ohms of reactance at 1 GHz and 106 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 24 V the part draws at most 1 uA, which is 24 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Board Layout

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.