Eaton STS232240U301 ESD Suppressor 24 V 30 pF
Eaton STS232240U301 ESD Suppressor 24 V 30 pF

Eaton STS232240U301 ESD Suppressor 24 V 30 pF

Share
STS232240U301: 24 V standoff TVS diode array, 2-channel, 30 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232240U301 ESD Suppressor 24 V 30 pF

    STS232240U301 at a glance: TVS diode array ESD suppressor, 24 V standoff, 55 V clamp, 2 channels, 30 pF, 350 W.

    Key Specifications

    ParameterValue
    Orderable part numberSTS232240U301
    Standoff voltage (VRWM)24 V
    Breakdown voltage (min / typ / max)26.7 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A43 V
    Clamping voltage at 5 A55 V
    Junction capacitance at 1 MHz, per line30 pF typ
    Channels2
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-8 kV contact / +/-15 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11148

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11148. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    What the Numbers Mean

    The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.

    At 5 A the clamp sits at 55 V, or 2.29 times the 24 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    30 pF per line is 5.3 ohms of reactance at 1 GHz and 53.1 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 24 V the part draws at most 1 uA, which is 24 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Where It Goes on the Board

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • ESD ratings are per IEC 61000-4-2 with the part as the first element the discharge meets. A connector shell or a mounting post that offers an easier path takes the strike instead, and the array never conducts.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.