| Parameter | Value |
|---|---|
| Orderable part number | STS234050U150 |
| Standoff voltage (VRWM) | 5 V |
| Breakdown voltage (min / typ / max) | 6 V / 9 V |
| Leakage current at VRWM | 0.5 uA max |
| Peak pulse power, 8/20 us, per line | 500 W |
| Clamping voltage at 1 A | 10 V |
| Clamping voltage at 24 A | 18 V |
| Junction capacitance at 1 MHz, per line | 3 pF typ / 3.5 pF max |
| Channels | 4 |
| Polarity | Unidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOT-23-6L (S23) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 3 |
| Operating junction temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11149 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data 11149. Values above are
read directly from the electrical table for this part number, not from the family
summary.
Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.
At 24 A the clamp sits at 18 V, or 3.60 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 500 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
3 pF per line is 53.1 ohms of reactance at 1 GHz and 531 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.
Standing at 5 V the part draws at most 0.5 uA, which is 2.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
All 4 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.
The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.
Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.
Can one package protect several lines?
Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.
How is the working voltage chosen?
Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.
Why does the package affect the rating?
It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd