    STS234050UL65 at a glance: TVS diode array ESD suppressor, 5 V standoff, 13 V clamp, 4 channels, 1.2 pF, 100 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS234050UL65
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V / 8 V / 10 V
    Leakage current at VRWM0.1 uA max
    Peak pulse power, 8/20 us, per line100 W
    Clamping voltage at 1 A11 V
    Clamping voltage at 8 A13 V
    Junction capacitance at 1 MHz, per line1.2 pF typ / 1.5 pF max
    Channels4
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOT-23-6L (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11149

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11149. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 8 A the clamp sits at 13 V, or 2.60 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 100 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    1.2 pF per line is 133 ohms of reactance at 1 GHz and 1,326 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.

    Standing at 5 V the part draws at most 0.1 uA, which is 0.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 4 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Placement in the Circuit

    Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.