| Parameter | Value |
|---|---|
| Orderable part number | STS321033B100 |
| Standoff voltage (VRWM) | 3.3 V |
| Breakdown voltage (min / typ / max) | 3.6 V |
| Leakage current at VRWM | 0.1 uA max |
| Peak pulse power, 8/20 us, per line | 350 W |
| Clamping voltage at 1 A | 6.5 V |
| Clamping voltage at 10 A | 12 V |
| Clamping voltage at 20 A | 17.5 V |
| Junction capacitance at 1 MHz, per line | 1 pF typ / 1.5 pF max |
| Channels | 1 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOD-323 (S32) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 3 |
| Operating junction temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11150 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data 11150. Values above are
read directly from the electrical table for this part number, not from the family
summary.
The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.
At 20 A the clamp sits at 17.5 V, or 5.30 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
1 pF per line is 159 ohms of reactance at 1 GHz and 1,592 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.
Standing at 3.3 V the part draws at most 0.1 uA, which is 0.33 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.
Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.
How is the working voltage chosen?
Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.
How many of these parts survive repeated strikes?
The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.