Eaton STS321033B401 ESD Suppressor 3.3 V 40 pF
Eaton STS321033B401 ESD Suppressor 3.3 V 40 pF

Eaton STS321033B401 ESD Suppressor 3.3 V 40 pF

Share
STS321033B401: 3.3 V standoff TVS diode array, 1-channel, 40 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321033B401 ESD Suppressor 3.3 V 40 pF

    STS321033B401 at a glance: TVS diode array ESD suppressor, 3.3 V standoff, 15 V clamp, 1 channel, 40 pF, 400 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS321033B401
    Standoff voltage (VRWM)3.3 V
    Breakdown voltage (min / typ / max)3.6 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line400 W
    Clamping voltage at 30 A15 V
    Junction capacitance at 1 MHz, per line40 pF typ / 60 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11151

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11151. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    At 30 A the clamp sits at 15 V, or 4.55 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 400 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    40 pF per line is 4.0 ohms of reactance at 1 GHz and 39.8 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 3.3 V the part draws at most 1 uA, which is 3.3 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    Placement in the Circuit

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • ESD ratings are per IEC 61000-4-2 with the part as the first element the discharge meets. A connector shell or a mounting post that offers an easier path takes the strike instead, and the array never conducts.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.