Eaton STS321050U182 ESD Suppressor 5 V 180 pF
Eaton STS321050U182 ESD Suppressor 5 V 180 pF

Eaton STS321050U182 ESD Suppressor 5 V 180 pF

Share
STS321050U182: 5 V standoff TVS diode array, 1-channel, 180 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321050U182 ESD Suppressor 5 V 180 pF

    STS321050U182 at a glance: TVS diode array ESD suppressor, 5 V standoff, 15 V clamp, 1 channel, 180 pF.

    Key Specifications

    ParameterValue
    Orderable part numberSTS321050U182
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V
    Leakage current at VRWM1 uA max
    Clamping voltage at 1 A9 V
    Clamping voltage at 22 A15 V
    Junction capacitance at 1 MHz, per line180 pF typ
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11152

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11152. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    What the Numbers Mean

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    At 22 A the clamp sits at 15 V, or 3.00 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet.

    180 pF per line is 0.88 ohms of reactance at 1 GHz and 8.8 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Where It Goes on the Board

    Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.