Eaton STS321050U852AH ESD Suppressor 5 V 850 pF
Eaton STS321050U852AH ESD Suppressor 5 V 850 pF

Eaton STS321050U852AH ESD Suppressor 5 V 850 pF

Share
STS321050U852AH: 5 V standoff TVS diode array, 1-channel, 850 pF per line, SOD-323 (S32), AEC-Q101.
    • Product Details
    • Download

    Eaton STS321050U852AH ESD Suppressor 5 V 850 pF

    STS321050U852AH at a glance: TVS diode array ESD suppressor, 5 V standoff, 17 V clamp, 1 channel, 850 pF, 2000 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS321050U852AH
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V / 7 V / 8 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line2000 W
    Clamping voltage at 50 A13 V
    Clamping voltage at 110 A17 V
    Junction capacitance at 1 MHz, per line850 pF typ / 1050 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1280

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1280. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 110 A the clamp sits at 17 V, or 3.40 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 2000 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    850 pF per line is 0.19 ohms of reactance at 1 GHz and 1.9 ohms at 100 MHz. A heavy load by design: this grade belongs on a supply rail or a low frequency line, where the capacitance is harmless and the low clamp is the point.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    Placement in the Circuit

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Is the automotive suffix a different die?
    It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.