Eaton STS321070U162AH ESD Suppressor 7 V 165 pF
Eaton STS321070U162AH ESD Suppressor 7 V 165 pF

Eaton STS321070U162AH ESD Suppressor 7 V 165 pF

Share
STS321070U162AH: 7 V standoff TVS diode array, 1-channel, 165 pF per line, SOD-323 (S32), AEC-Q101.
    • Product Details
    • Download

    Eaton STS321070U162AH ESD Suppressor 7 V 165 pF

    STS321070U162AH at a glance: TVS diode array ESD suppressor, 7 V standoff, 20 V clamp, 1 channel, 165 pF, 350 W.

    Specification Table

    ParameterValue
    Orderable part numberSTS321070U162AH
    Standoff voltage (VRWM)7 V
    Breakdown voltage (min / typ / max)7.5 V / 8.5 V / 9 V
    Leakage current at VRWM0.5 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A15 V
    Clamping voltage at 25 A20 V
    Junction capacitance at 1 MHz, per line165 pF typ / 200 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1279

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1279. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 25 A the clamp sits at 20 V, or 2.86 times the 7 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    165 pF per line is 0.96 ohms of reactance at 1 GHz and 9.6 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 7 V the part draws at most 0.5 uA, which is 3.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    Board Layout

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.