    STS321120U372 at a glance: TVS diode array ESD suppressor, 12 V standoff, 28 V clamp, 1 channel, 370 pF, 2000 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS321120U372
    Standoff voltage (VRWM)12 V
    Breakdown voltage (min / typ / max)13 V / 14.4 V / 17 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line2000 W
    Clamping voltage at 20 A19 V
    Clamping voltage at 40 A24 V
    Clamping voltage at 70 A28 V
    Junction capacitance at 1 MHz, per line370 pF typ / 450 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11145

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11145. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    At 70 A the clamp sits at 28 V, or 2.33 times the 12 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 2000 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    370 pF per line is 0.43 ohms of reactance at 1 GHz and 4.3 ohms at 100 MHz. A heavy load by design: this grade belongs on a supply rail or a low frequency line, where the capacitance is harmless and the low clamp is the point.

    Standing at 12 V the part draws at most 1 uA, which is 12 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    Layout and Placement

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.