STS321120U901AH: 12 V standoff TVS diode array, 1-channel, 90 pF per line, SOD-323 (S32), AEC-Q101.
    • Product Details
    • Download

    Eaton STS321120U901AH ESD Suppressor 12 V 90 pF

    STS321120U901AH at a glance: TVS diode array ESD suppressor, 12 V standoff, 18 V clamp, 1 channel, 90 pF, 350 W.

    Key Specifications

    ParameterValue
    Orderable part numberSTS321120U901AH
    Standoff voltage (VRWM)12 V
    Breakdown voltage (min / typ / max)13.3 V / 13.5 V / 16 V
    Leakage current at VRWM0.1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A18 V
    Junction capacitance at 1 MHz, per line90 pF typ / 100 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1279

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1279. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    What the Numbers Mean

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    At 1 A the clamp sits at 18 V, or 1.50 times the 12 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    90 pF per line is 1.8 ohms of reactance at 1 GHz and 17.7 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 12 V the part draws at most 0.1 uA, which is 1.2 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    Where It Goes on the Board

    Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • The capacitance figure is at zero bias. At the working voltage the junction depletes and the value falls, so the loading on a live bus is lower than the table suggests.

    Frequently Asked Questions

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.