Eaton STS321150B100 TVS Diode 15 V 350 W
Eaton STS321150B100 TVS Diode 15 V 350 W

Eaton STS321150B100 TVS Diode 15 V 350 W

Share
STS321150B100: 15 V standoff TVS diode array, 1-channel, 1 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321150B100 TVS Diode 15 V 350 W

    STS321150B100 at a glance: TVS diode array ESD suppressor, 15 V standoff, 40 V clamp, 1 channel, 1 pF, 350 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS321150B100
    Standoff voltage (VRWM)15 V
    Breakdown voltage (min / typ / max)16.7 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A25 V
    Clamping voltage at 10 A40 V
    Junction capacitance at 1 MHz, per line1 pF typ / 1.5 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11150

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11150. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    At 10 A the clamp sits at 40 V, or 2.67 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    1 pF per line is 159 ohms of reactance at 1 GHz and 1,592 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.

    Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Layout and Placement

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.