| Parameter | Value |
|---|---|
| Orderable part number | STS321150B100AH |
| Standoff voltage (VRWM) | 15 V |
| Breakdown voltage (min / typ / max) | 16.7 V |
| Leakage current at VRWM | 1 uA max |
| Peak pulse power, 8/20 us, per line | 350 W |
| Clamping voltage at 1 A | 25 V |
| Junction capacitance at 1 MHz, per line | 1 pF typ / 1.5 pF max |
| Channels | 1 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOD-323 (S32) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +150 °C |
| Qualification | AEC-Q101 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1278 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data ELX1278. Values above are
read directly from the electrical table for this part number, not from the family
summary.
The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.
At 1 A the clamp sits at 25 V, or 1.67 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
1 pF per line is 159 ohms of reactance at 1 GHz and 1,592 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.
Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.
Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.
Is the automotive suffix a different die?
It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.
Why does the clamp voltage differ from the breakdown voltage?
Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.
Can one package protect several lines?
Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd