Eaton STS321150U332 TVS Diode 15 V 2000 W
Eaton STS321150U332 TVS Diode 15 V 2000 W

Eaton STS321150U332 TVS Diode 15 V 2000 W

Share
STS321150U332: 15 V standoff TVS diode array, 1-channel, 330 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321150U332 TVS Diode 15 V 2000 W

    STS321150U332 at a glance: TVS diode array ESD suppressor, 15 V standoff, 30 V clamp, 1 channel, 330 pF, 2000 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS321150U332
    Standoff voltage (VRWM)15 V
    Breakdown voltage (min / typ / max)16 V / 17.2 V / 20 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line2000 W
    Clamping voltage at 25 A25 V
    Clamping voltage at 55 A30 V
    Junction capacitance at 1 MHz, per line330 pF typ / 400 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11145

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11145. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    At 55 A the clamp sits at 30 V, or 2.00 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 2000 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    330 pF per line is 0.48 ohms of reactance at 1 GHz and 4.8 ohms at 100 MHz. A heavy load by design: this grade belongs on a supply rail or a low frequency line, where the capacitance is harmless and the low clamp is the point.

    Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    Layout and Placement

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • The capacitance figure is at zero bias. At the working voltage the junction depletes and the value falls, so the loading on a live bus is lower than the table suggests.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message