| Parameter | Value |
|---|---|
| Orderable part number | STS321150U332AH |
| Standoff voltage (VRWM) | 15 V |
| Breakdown voltage (min / typ / max) | 16 V / 17.2 V / 20 V |
| Leakage current at VRWM | 1 uA max |
| Peak pulse power, 8/20 us, per line | 2000 W |
| Clamping voltage at 25 A | 25 V |
| Clamping voltage at 50 A | 28 V |
| Clamping voltage at 55 A | 30 V |
| Junction capacitance at 1 MHz, per line | 330 pF typ / 400 pF max |
| Channels | 1 |
| Polarity | Unidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOD-323 (S32) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +150 °C |
| Qualification | AEC-Q101 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1280 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data ELX1280. Values above are
read directly from the electrical table for this part number, not from the family
summary.
Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.
At 55 A the clamp sits at 30 V, or 2.00 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 2000 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
330 pF per line is 0.48 ohms of reactance at 1 GHz and 4.8 ohms at 100 MHz. A heavy load by design: this grade belongs on a supply rail or a low frequency line, where the capacitance is harmless and the low clamp is the point.
Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.
Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.
Is the automotive suffix a different die?
It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.
Can one package protect several lines?
Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.
Why does the clamp voltage differ from the breakdown voltage?
Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd