Eaton STS321150U332AH TVS Diode 15 V 2000 W
Eaton STS321150U332AH TVS Diode 15 V 2000 W

Eaton STS321150U332AH TVS Diode 15 V 2000 W

Share
STS321150U332AH: 15 V standoff TVS diode array, 1-channel, 330 pF per line, SOD-323 (S32), AEC-Q101.
    • Product Details
    • Download

    Eaton STS321150U332AH TVS Diode 15 V 2000 W

    STS321150U332AH at a glance: TVS diode array ESD suppressor, 15 V standoff, 30 V clamp, 1 channel, 330 pF, 2000 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS321150U332AH
    Standoff voltage (VRWM)15 V
    Breakdown voltage (min / typ / max)16 V / 17.2 V / 20 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line2000 W
    Clamping voltage at 25 A25 V
    Clamping voltage at 50 A28 V
    Clamping voltage at 55 A30 V
    Junction capacitance at 1 MHz, per line330 pF typ / 400 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1280

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1280. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 55 A the clamp sits at 30 V, or 2.00 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 2000 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    330 pF per line is 0.48 ohms of reactance at 1 GHz and 4.8 ohms at 100 MHz. A heavy load by design: this grade belongs on a supply rail or a low frequency line, where the capacitance is harmless and the low clamp is the point.

    Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Placement in the Circuit

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    Is the automotive suffix a different die?
    It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.