| Parameter | Value |
|---|---|
| Orderable part number | STS321360B141AH |
| Standoff voltage (VRWM) | 36 V |
| Breakdown voltage (min / typ / max) | 40 V / 42 V / 47.5 V |
| Leakage current at VRWM | 0.2 uA max |
| Peak pulse power, 8/20 us, per line | 400 W |
| Clamping voltage at 1 A | 60 V |
| Clamping voltage at 6 A | 70 V |
| Junction capacitance at 1 MHz, per line | 14 pF typ / 25 pF max |
| Channels | 1 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOD-323 (S32) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +150 °C |
| Qualification | AEC-Q101 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1279 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data ELX1279. Values above are
read directly from the electrical table for this part number, not from the family
summary.
The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.
At 6 A the clamp sits at 70 V, or 1.94 times the 36 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 400 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
14 pF per line is 11.4 ohms of reactance at 1 GHz and 114 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.
Standing at 36 V the part draws at most 0.2 uA, which is 7.2 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.
Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.
Why does the clamp voltage differ from the breakdown voltage?
Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.
Why does the package affect the rating?
It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd