STS321360U351: 36 V standoff TVS diode array, 1-channel, 35 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321360U351 ESD Suppressor 36 V 35 pF

    STS321360U351 at a glance: TVS diode array ESD suppressor, 36 V standoff, 65 V clamp, 1 channel, 35 pF, 500 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS321360U351
    Standoff voltage (VRWM)36 V
    Breakdown voltage (min / typ / max)39 V
    Leakage current at VRWM0.1 uA max
    Peak pulse power, 8/20 us, per line500 W
    Clamping voltage at 1 A55 V
    Clamping voltage at 6 A65 V
    Junction capacitance at 1 MHz, per line35 pF typ / 45 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11152

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11152. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    At 6 A the clamp sits at 65 V, or 1.81 times the 36 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 500 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    35 pF per line is 4.5 ohms of reactance at 1 GHz and 45.5 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 36 V the part draws at most 0.1 uA, which is 3.6 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Layout and Placement

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.