Eaton STS521033B101AH ESD Suppressor 3.3 V 10 pF
Eaton STS521033B101AH ESD Suppressor 3.3 V 10 pF

Eaton STS521033B101AH ESD Suppressor 3.3 V 10 pF

Share
STS521033B101AH: 3.3 V standoff TVS diode array, 1-channel, 10 pF per line, SOD-523 (S52), AEC-Q101.
    • Product Details
    • Download

    Eaton STS521033B101AH ESD Suppressor 3.3 V 10 pF

    STS521033B101AH at a glance: TVS diode array ESD suppressor, 3.3 V standoff, 12 V clamp, 1 channel, 10 pF, 80 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS521033B101AH
    Standoff voltage (VRWM)3.3 V
    Breakdown voltage (min / typ / max)3.6 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line80 W
    Clamping voltage at 1 A8 V
    Clamping voltage at 7 A12 V
    Junction capacitance at 1 MHz, per line10 pF typ / 20 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1281

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1281. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 7 A the clamp sits at 12 V, or 3.64 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 80 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    10 pF per line is 15.9 ohms of reactance at 1 GHz and 159 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 3.3 V the part draws at most 1 uA, which is 3.3 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    Placement in the Circuit

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    Is the automotive suffix a different die?
    It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Shenzhen Gaorunxin Technology Co., Ltd