Eaton STS521033U112 ESD Suppressor 3.3 V 110 pF
Eaton STS521033U112 ESD Suppressor 3.3 V 110 pF

Eaton STS521033U112 ESD Suppressor 3.3 V 110 pF

Share
STS521033U112: 3.3 V standoff TVS diode array, 1-channel, 110 pF per line, SOD-523 (S52), commercial grade.
    • Product Details
    • Download

    Eaton STS521033U112 ESD Suppressor 3.3 V 110 pF

    STS521033U112 at a glance: TVS diode array ESD suppressor, 3.3 V standoff, 15 V clamp, 1 channel, 110 pF, 250 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS521033U112
    Standoff voltage (VRWM)3.3 V
    Breakdown voltage (min / typ / max)4 V
    Leakage current at VRWM5 uA max
    Peak pulse power, 8/20 us, per line250 W
    Clamping voltage at 15 A (typ)15 V
    Junction capacitance at 1 MHz, per line110 pF typ
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11159

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11159. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    At 15 A the clamp sits at 15 V, or 4.55 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 250 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    110 pF per line is 1.4 ohms of reactance at 1 GHz and 14.5 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 3.3 V the part draws at most 5 uA, which is 16.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    Placement in the Circuit

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • ESD ratings are per IEC 61000-4-2 with the part as the first element the discharge meets. A connector shell or a mounting post that offers an easier path takes the strike instead, and the array never conducts.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.