STS521050B331AH: 5 V standoff TVS diode array, 1-channel, 80 pF per line, SOD-523 (S52), AEC-Q101.
    • Product Details
    • Download

    Eaton STS521050B331AH ESD Suppressor 5 V 80 pF

    STS521050B331AH at a glance: TVS diode array ESD suppressor, 5 V standoff, 14 V clamp, 1 channel, 80 pF, 300 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS521050B331AH
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)5.5 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line300 W
    Clamping voltage at 1 A9 V
    Clamping voltage at 20 A14 V
    Junction capacitance at 1 MHz, per line80 pF typ
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1281

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1281. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.

    At 20 A the clamp sits at 14 V, or 2.80 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 300 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    80 pF per line is 2.0 ohms of reactance at 1 GHz and 19.9 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Layout and Placement

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Is the automotive suffix a different die?
    It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd