Eaton STS521120U351AH ESD Suppressor 12 V 35 pF
Eaton STS521120U351AH ESD Suppressor 12 V 35 pF

Eaton STS521120U351AH ESD Suppressor 12 V 35 pF

Share
STS521120U351AH: 12 V standoff TVS diode array, 1-channel, 35 pF per line, SOD-523 (S52), AEC-Q101.
    • Product Details
    • Download

    Eaton STS521120U351AH ESD Suppressor 12 V 35 pF

    STS521120U351AH at a glance: TVS diode array ESD suppressor, 12 V standoff, 25 V clamp, 1 channel, 35 pF, 120 W.

    Specification Table

    ParameterValue
    Orderable part numberSTS521120U351AH
    Standoff voltage (VRWM)12 V
    Breakdown voltage (min / typ / max)13.3 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line120 W
    Clamping voltage at 1 A18 V
    Clamping voltage at 6 A25 V
    Junction capacitance at 1 MHz, per line35 pF typ / 40 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1281

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1281. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 6 A the clamp sits at 25 V, or 2.08 times the 12 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 120 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    35 pF per line is 4.5 ohms of reactance at 1 GHz and 45.5 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 12 V the part draws at most 1 uA, which is 12 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Board Layout

    Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message