Eaton STS521240U161 TVS Diode 24 V 200 W
Eaton STS521240U161 TVS Diode 24 V 200 W

Eaton STS521240U161 TVS Diode 24 V 200 W

Share
STS521240U161: 24 V standoff TVS diode array, 1-channel, 16 pF per line, SOD-523 (S52), commercial grade.
    • Product Details
    • Download

    Eaton STS521240U161 TVS Diode 24 V 200 W

    STS521240U161 at a glance: TVS diode array ESD suppressor, 24 V standoff, 48 V clamp, 1 channel, 16 pF, 200 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS521240U161
    Standoff voltage (VRWM)24 V
    Breakdown voltage (min / typ / max)26.7 V
    Leakage current at VRWM0.1 uA max
    Peak pulse power, 8/20 us, per line200 W
    Clamping voltage at 1 A40 V
    Clamping voltage at 4 A48 V
    Junction capacitance at 1 MHz, per line16 pF typ / 25 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11159

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11159. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 4 A the clamp sits at 48 V, or 2.00 times the 24 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 200 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    16 pF per line is 9.9 ohms of reactance at 1 GHz and 99.5 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 24 V the part draws at most 0.1 uA, which is 2.4 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Placement in the Circuit

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.