Eaton STS521240U161AH ESD Suppressor 24 V 16 pF
Eaton STS521240U161AH ESD Suppressor 24 V 16 pF

Eaton STS521240U161AH ESD Suppressor 24 V 16 pF

Share
STS521240U161AH: 24 V standoff TVS diode array, 1-channel, 16 pF per line, SOD-523 (S52), AEC-Q101.
    • Product Details
    • Download

    Eaton STS521240U161AH ESD Suppressor 24 V 16 pF

    STS521240U161AH at a glance: TVS diode array ESD suppressor, 24 V standoff, 48 V clamp, 1 channel, 16 pF, 200 W.

    Key Specifications

    ParameterValue
    Orderable part numberSTS521240U161AH
    Standoff voltage (VRWM)24 V
    Breakdown voltage (min / typ / max)26.7 V
    Leakage current at VRWM0.1 uA max
    Peak pulse power, 8/20 us, per line200 W
    Clamping voltage at 1 A40 V
    Clamping voltage at 4 A48 V
    Junction capacitance at 1 MHz, per line16 pF typ / 25 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1281

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1281. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    What the Numbers Mean

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    At 4 A the clamp sits at 48 V, or 2.00 times the 24 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 200 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    16 pF per line is 9.9 ohms of reactance at 1 GHz and 99.5 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 24 V the part draws at most 0.1 uA, which is 2.4 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Where It Goes on the Board

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.