Eaton TL1011V2-R110-R 110 nH Coupled TLVR Inductor
Eaton TL1011V2-R110-R 110 nH Coupled TLVR Inductor

Eaton TL1011V2-R110-R 110 nH Coupled TLVR Inductor

Share
TL1011V2-R110-R: trans-inductor regulator coupled inductor, Lpri 110 nH, Lsec 110 nH, FLL 79 nH, Kps 0.95, Irms 70 A.
    • Product Details
    • Download

    Eaton TL1011V2-R110-R 110 nH Coupled TLVR Inductor

    TL1011V2-R110-R at a glance: trans-inductor regulator coupled inductor, Lpri 110 nH, Lsec 110 nH, FLL 79 nH, Kps 0.95, Irms 70 A.

    Electrical Specifications

    ParameterValue
    Orderable part numberTL1011V2-R110-R
    Primary inductance Lpri (terminals 3-4)110 nH ±10%
    Secondary inductance Lsec (terminals 1-2)110 nH ±10%
    FLL minimum at Isat179 nH
    DCR primary @ +20 °C0.6 mOhm
    DCR secondary @ +20 °C0.15 mOhm
    Irms secondary (40 °C rise)70 A
    Isat1 (20 % rolloff @ +25 °C)104 A
    Isat2 (20 % rolloff @ +100 °C)89 A
    Isat3 (20 % rolloff @ +125 °C)83 A
    K-factor (Bp-p = K x L x dI x 10^-3)340
    Coupling coefficient Kps0.95
    Package9.6 x 6.4 mm, 11.0 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1154

    Dimensions and Pad Layout

    TL1011V2-R110-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1154: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    In a multiphase buck a TLVR allows a smaller inductance than a conventional design, because the current slew is set by the loop rather than by the winding alone. Smaller inductance means faster response and less board area for the same current.

    The secondary winding drops about 10.5 mV at its 70 A rating and dissipates roughly 0.735 W there. That is the loss the loop carries on top of the phase windings.

    The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.

    With Kps at 0.95 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.

    Within the TL1011V2 family this is value 4 of 7, in a range from 70 to 170 nH.

    Positioning in the Range

    The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.

    • The secondary loop is part of the power stage. Layout inductance in that loop shows up directly as a slower transient, so keep the return path short and symmetric between phases.
    • Typical applications: multi-phase and vcore regulators; voltage regulator modules (vrms) and high power density vrms; server and desktop; central processing unit (cpu); graphics processing unit (gpu).
    • Design note: ripple from FLL, transient from Kps, loss from the primary DCR at the phase current. The secondary DCR only carries the difference current.

    Frequently Asked Questions

    Why is the primary DCR larger than the secondary?
    The primary carries the phase current through the full winding; the secondary is usually a single turn or a short winding because it only has to carry the difference current. The two are measured between different terminal pairs and are not interchangeable.

    How do I estimate core loss?
    Use the K-factor with the flux swing: Bp-p = K x L x delta-I x 10^-3, with L in microhenry and delta-I in amp, which gives gauss. Read the core-loss curve at that amplitude and the switching frequency.

    Can I use this part as an ordinary inductor?
    Only if you leave the secondary open. With the secondary connected to the other phases the part is part of a loop and its effective inductance depends on what the rest of the loop is doing.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products