| Parameter | Value |
|---|---|
| Orderable part number | TL1211V1-R110-R |
| Primary inductance Lpri (terminals 3-4) | 110 nH ±10% |
| Secondary inductance Lsec (terminals 1-2) | 110 nH ±10% |
| FLL minimum at Isat1 | 79 nH |
| DCR primary @ +20 °C | 0.6 mOhm |
| DCR secondary @ +20 °C | 0.125 mOhm |
| Irms secondary (40 °C rise) | 75 A |
| Isat1 (20 % rolloff @ +25 °C) | 114 A |
| Isat2 (20 % rolloff @ +100 °C) | 99 A |
| Isat3 (20 % rolloff @ +125 °C) | 91 A |
| K-factor (Bp-p = K x L x dI x 10^-3) | 313 |
| Coupling coefficient Kps | 0.95 |
| Package | 12.0 x 6.0 mm, 11.05 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1156 |

Drawing reproduced from Eaton Technical Data ELX1156: outline views
with rated mm dimensions, pad layout and marking.
The coupling coefficient Kps is the figure that decides how much of a transient the loop can absorb. At 0.93 roughly nine tenths of the flux links both windings, so the secondary carries its share of the phase current automatically.
The secondary winding drops about 9.38 mV at its 75 A rating and dissipates roughly 0.703 W there. That is the loss the loop carries on top of the phase windings.
The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.
With Kps at 0.95 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.
Within the TL1211V1 family this is value 4 of 8, in a range from 70 to 200 nH.
The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.
Why is the primary DCR larger than the secondary?
The primary carries the phase current through the full winding; the secondary is usually a single turn or a short winding because it only has to carry the difference current. The two are measured between different terminal pairs and are not interchangeable.
What does a trans-inductor actually do that a normal inductor does not?
It couples the phases. The secondary windings form a closed loop, so a current step in one phase induces a voltage that drives current out of the other phases immediately. The converter responds faster than the control loop alone could manage, and the output capacitor sees a smaller excursion.
Which inductance do I use for the ripple calculation?
FLL, the full-load inductance, because that is the value at the current the converter actually runs at. OCL is the zero-bias figure and overstates the inductance at load; using it makes the ripple look smaller than it is.