TL1211V1-R150-R: trans-inductor regulator coupled inductor, Lpri 150 nH, Lsec 150 nH, FLL 108 nH, Kps 0.96, Irms 75 A.
    • Product Details
    • Download

    Eaton TL1211V1-R150-R 150 nH Coupled TLVR Inductor

    TL1211V1-R150-R at a glance: trans-inductor regulator coupled inductor, Lpri 150 nH, Lsec 150 nH, FLL 108 nH, Kps 0.96, Irms 75 A.

    Specification Table

    ParameterValue
    Orderable part numberTL1211V1-R150-R
    Primary inductance Lpri (terminals 3-4)150 nH ±10%
    Secondary inductance Lsec (terminals 1-2)150 nH ±10%
    FLL minimum at Isat1108 nH
    DCR primary @ +20 °C0.6 mOhm
    DCR secondary @ +20 °C0.125 mOhm
    Irms secondary (40 °C rise)75 A
    Isat1 (20 % rolloff @ +25 °C)84 A
    Isat2 (20 % rolloff @ +100 °C)73 A
    Isat3 (20 % rolloff @ +125 °C)67 A
    K-factor (Bp-p = K x L x dI x 10^-3)313
    Coupling coefficient Kps0.96
    Package12.0 x 6.0 mm, 11.05 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1156

    Mechanical Drawing

    TL1211V1-R150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1156: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A trans-inductor regulator does not give each phase its own inductor and stop there. The secondary windings are tied into one series loop, so when a phase is driven, the loop forces every other phase to deliver current as well. The load step is shared before the controller has finished reacting.

    The secondary winding drops about 9.38 mV at its 75 A rating and dissipates roughly 0.703 W there. That is the loss the loop carries on top of the phase windings.

    The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.

    With Kps at 0.96 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.

    Within the TL1211V1 family this is value 6 of 8, in a range from 70 to 200 nH.

    Positioning in the Range

    The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.

    • The secondary loop is part of the power stage. Layout inductance in that loop shows up directly as a slower transient, so keep the return path short and symmetric between phases.
    • Typical applications: multi-phase and vcore regulators; voltage regulator modules (vrms) and high power density vrms; server and desktop; central processing unit (cpu); graphics processing unit (gpu).
    • Design note: ripple from FLL, transient from Kps, loss from the primary DCR at the phase current. The secondary DCR only carries the difference current.

    Frequently Asked Questions

    How do I estimate core loss?
    Use the K-factor with the flux swing: Bp-p = K x L x delta-I x 10^-3, with L in microhenry and delta-I in amp, which gives gauss. Read the core-loss curve at that amplitude and the switching frequency.

    How do I estimate core loss?
    Use the K-factor with the flux swing: Bp-p = K x L x delta-I x 10^-3, with L in microhenry and delta-I in amp, which gives gauss. Read the core-loss curve at that amplitude and the switching frequency.

    What does a trans-inductor actually do that a normal inductor does not?
    It couples the phases. The secondary windings form a closed loop, so a current step in one phase induces a voltage that drives current out of the other phases immediately. The converter responds faster than the control loop alone could manage, and the output capacitor sees a smaller excursion.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message