| Parameter | Value |
|---|---|
| Orderable part number | TL1211V2-R070-R |
| Primary inductance Lpri (terminals 3-4) | 70 nH ±10% |
| Secondary inductance Lsec (terminals 1-2) | 70 nH ±10% |
| FLL minimum at Isat1 | 50 nH |
| DCR primary @ +20 °C | 0.37 mOhm |
| DCR secondary @ +20 °C | 0.125 mOhm |
| Irms secondary (40 °C rise) | 75 A |
| Isat1 (20 % rolloff @ +25 °C) | 170 A |
| Isat2 (20 % rolloff @ +100 °C) | 145 A |
| Isat3 (20 % rolloff @ +125 °C) | 135 A |
| K-factor (Bp-p = K x L x dI x 10^-3) | 328 |
| Coupling coefficient Kps | 0.93 |
| Package | 12.0 x 6.0 mm, 11.0 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1157 |

Drawing reproduced from Eaton Technical Data ELX1157: outline views
with rated mm dimensions, pad layout and marking.
A trans-inductor regulator does not give each phase its own inductor and stop there. The secondary windings are tied into one series loop, so when a phase is driven, the loop forces every other phase to deliver current as well. The load step is shared before the controller has finished reacting.
The secondary winding drops about 9.38 mV at its 75 A rating and dissipates roughly 0.703 W there. That is the loss the loop carries on top of the phase windings.
The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.
With Kps at 0.93 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.
Within the TL1211V2 family this is value 1 of 8, in a range from 70 to 200 nH.
The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.
Can I use this part as an ordinary inductor?
Only if you leave the secondary open. With the secondary connected to the other phases the part is part of a loop and its effective inductance depends on what the rest of the loop is doing.
What is a good coupling coefficient?
Higher is better for transient response, but it also couples more of the ripple between phases. Values around 0.9 to 0.95 are typical; below about 0.85 the loop stops doing much work and the part behaves like a plain inductor with extra terminals.
How do I estimate core loss?
Use the K-factor with the flux swing: Bp-p = K x L x delta-I x 10^-3, with L in microhenry and delta-I in amp, which gives gauss. Read the core-loss curve at that amplitude and the switching frequency.