| Parameter | Value |
|---|---|
| Orderable part number | TL1212V2-R080-R |
| Primary inductance Lpri (terminals 3-4) | 80 nH ±10% |
| Secondary inductance Lsec (terminals 1-2) | 80 nH ±10% |
| FLL minimum at Isat1 | 57 nH |
| DCR primary @ +20 °C | 0.37 mOhm |
| DCR secondary @ +20 °C | 0.125 mOhm |
| Irms secondary (40 °C rise) | 75 A |
| Isat1 (20 % rolloff @ +25 °C) | 163 A |
| Isat2 (20 % rolloff @ +100 °C) | 140 A |
| Isat3 (20 % rolloff @ +125 °C) | 129 A |
| K-factor (Bp-p = K x L x dI x 10^-3) | 308 |
| Coupling coefficient Kps | 0.92 |
| Package | 12.0 x 6.0 mm, 12.1 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1159 |

Drawing reproduced from Eaton Technical Data ELX1159: outline views
with rated mm dimensions, pad layout and marking.
In a multiphase buck a TLVR allows a smaller inductance than a conventional design, because the current slew is set by the loop rather than by the winding alone. Smaller inductance means faster response and less board area for the same current.
The secondary winding drops about 9.38 mV at its 75 A rating and dissipates roughly 0.703 W there. That is the loss the loop carries on top of the phase windings.
The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.
With Kps at 0.92 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.
Within the TL1212V2 family this is value 2 of 6, in a range from 70 to 170 nH.
The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.
What does a trans-inductor actually do that a normal inductor does not?
It couples the phases. The secondary windings form a closed loop, so a current step in one phase induces a voltage that drives current out of the other phases immediately. The converter responds faster than the control loop alone could manage, and the output capacitor sees a smaller excursion.
Why is the primary DCR larger than the secondary?
The primary carries the phase current through the full winding; the secondary is usually a single turn or a short winding because it only has to carry the difference current. The two are measured between different terminal pairs and are not interchangeable.
What is a good coupling coefficient?
Higher is better for transient response, but it also couples more of the ripple between phases. Values around 0.9 to 0.95 are typical; below about 0.85 the loop stops doing much work and the part behaves like a plain inductor with extra terminals.