| Parameter | Value |
|---|---|
| Orderable part number | TL1212V2-R170-R |
| Primary inductance Lpri (terminals 3-4) | 170 nH ±10% |
| Secondary inductance Lsec (terminals 1-2) | 170 nH ±10% |
| FLL minimum at Isat1 | 122 nH |
| DCR primary @ +20 °C | 0.37 mOhm |
| DCR secondary @ +20 °C | 0.125 mOhm |
| Irms secondary (40 °C rise) | 75 A |
| Isat1 (20 % rolloff @ +25 °C) | 76 A |
| Isat2 (20 % rolloff @ +100 °C) | 66 A |
| Isat3 (20 % rolloff @ +125 °C) | 61 A |
| K-factor (Bp-p = K x L x dI x 10^-3) | 308 |
| Coupling coefficient Kps | 0.96 |
| Package | 12.0 x 6.0 mm, 12.1 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1159 |

Drawing reproduced from Eaton Technical Data ELX1159: outline views
with rated mm dimensions, pad layout and marking.
In a multiphase buck a TLVR allows a smaller inductance than a conventional design, because the current slew is set by the loop rather than by the winding alone. Smaller inductance means faster response and less board area for the same current.
The secondary winding drops about 9.38 mV at its 75 A rating and dissipates roughly 0.703 W there. That is the loss the loop carries on top of the phase windings.
The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.
With Kps at 0.96 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.
Within the TL1212V2 family this is value 6 of 6, in a range from 70 to 170 nH.
The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.
What is a good coupling coefficient?
Higher is better for transient response, but it also couples more of the ripple between phases. Values around 0.9 to 0.95 are typical; below about 0.85 the loop stops doing much work and the part behaves like a plain inductor with extra terminals.
What is a good coupling coefficient?
Higher is better for transient response, but it also couples more of the ripple between phases. Values around 0.9 to 0.95 are typical; below about 0.85 the loop stops doing much work and the part behaves like a plain inductor with extra terminals.
Which inductance do I use for the ripple calculation?
FLL, the full-load inductance, because that is the value at the current the converter actually runs at. OCL is the zero-bias figure and overstates the inductance at load; using it makes the ripple look smaller than it is.