Eaton TLP1013V1-R170-R 170 nH Coupled TLVR Inductor
Eaton TLP1013V1-R170-R 170 nH Coupled TLVR Inductor

Eaton TLP1013V1-R170-R 170 nH Coupled TLVR Inductor

Share
TLP1013V1-R170-R: trans-inductor regulator coupled inductor, Lpri 170 nH, Lsec 170 nH, FLL 122 nH, Kps 0.96, Irms 72 A.
    • Product Details
    • Download

    Eaton TLP1013V1-R170-R 170 nH Coupled TLVR Inductor

    TLP1013V1-R170-R at a glance: trans-inductor regulator coupled inductor, Lpri 170 nH, Lsec 170 nH, FLL 122 nH, Kps 0.96, Irms 72 A.

    Ratings at a Glance

    ParameterValue
    Orderable part numberTLP1013V1-R170-R
    Primary inductance Lpri (terminals 3-4)170 nH ±10%
    Secondary inductance Lsec (terminals 1-2)170 nH ±10%
    FLL minimum at Isat1122 nH
    DCR primary @ +20 °C0.53 mOhm
    DCR secondary @ +20 °C0.14 mOhm
    Irms secondary (40 °C rise)72 A
    Isat1 (20 % rolloff @ +25 °C)66 A
    Isat2 (20 % rolloff @ +100 °C)58 A
    Isat3 (20 % rolloff @ +125 °C)53 A
    K-factor (Bp-p = K x L x dI x 10^-3)352
    Coupling coefficient Kps0.96
    Package9.6 x 6.4 mm, 13.15 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1158

    Outline Drawing

    TLP1013V1-R170-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1158: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    In a multiphase buck a TLVR allows a smaller inductance than a conventional design, because the current slew is set by the loop rather than by the winding alone. Smaller inductance means faster response and less board area for the same current.

    The secondary winding drops about 10.1 mV at its 72 A rating and dissipates roughly 0.726 W there. That is the loss the loop carries on top of the phase windings.

    The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.

    With Kps at 0.96 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.

    Within the TLP1013V1 family this is value 4 of 4, in a range from 105 to 170 nH.

    Series Positioning

    The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.

    • The secondary loop is part of the power stage. Layout inductance in that loop shows up directly as a slower transient, so keep the return path short and symmetric between phases.
    • Typical applications: multi-phase and vcore regulators; voltage regulator modules (vrms) and high power density vrms; server and desktop; central processing unit (cpu); graphics processing unit (gpu).
    • Design note: ripple from FLL, transient from Kps, loss from the primary DCR at the phase current. The secondary DCR only carries the difference current.

    Frequently Asked Questions

    Can I use this part as an ordinary inductor?
    Only if you leave the secondary open. With the secondary connected to the other phases the part is part of a loop and its effective inductance depends on what the rest of the loop is doing.

    Can I use this part as an ordinary inductor?
    Only if you leave the secondary open. With the secondary connected to the other phases the part is part of a loop and its effective inductance depends on what the rest of the loop is doing.

    How do I estimate core loss?
    Use the K-factor with the flux swing: Bp-p = K x L x delta-I x 10^-3, with L in microhenry and delta-I in amp, which gives gauss. Read the core-loss curve at that amplitude and the switching frequency.