| Parameter | Value |
|---|---|
| Orderable part number | TVSA02V05C004 |
| Standoff voltage (VRWM) | 5 V |
| Breakdown voltage (min / typ / max) | 10 V |
| Clamping voltage at 1 A | 17 V |
| Junction capacitance at 1 MHz, per line | 4 pF typ |
| Packaging | 15,000 pcs per reel |
| Channels | 1 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-8 kV contact / +/-15 kV air |
| Package | 0201 |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data DS4072 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data DS4072. Values above are
read directly from the electrical table for this part number, not from the family
summary.
Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.
At 1 A the clamp sits at 17 V, or 3.40 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet.
4 pF per line is 39.8 ohms of reactance at 1 GHz and 398 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.
The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.
Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.
How many of these parts survive repeated strikes?
The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.
Does the array capacitance disturb the signal?
It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.
Why does the package affect the rating?
It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.