Eaton TVSL02V12C008 ESD Suppressor 12 V 8.5 pF
Eaton TVSL02V12C008 ESD Suppressor 12 V 8.5 pF

Eaton TVSL02V12C008 ESD Suppressor 12 V 8.5 pF

Share
TVSL02V12C008: 12 V standoff TVS diode array, 1-channel, 8.5 pF per line, 0201 (0603 metric), commercial grade.
    • Product Details
    • Download

    Eaton TVSL02V12C008 ESD Suppressor 12 V 8.5 pF

    TVSL02V12C008 at a glance: TVS diode array ESD suppressor, 12 V standoff, 15.8 V clamp, 1 channel, 8.5 pF, 60 W.

    Specification Table

    ParameterValue
    Orderable part numberTVSL02V12C008
    Standoff voltage (VRWM)12 V
    Breakdown voltage (min / typ / max)15.5 V / 19 V / 22.5 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line60 W
    Clamping voltage at 1 A, TLP 100 ns (typ)15.8 V
    Junction capacitance at 1 MHz, per line8.5 pF typ
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-25 kV contact / +/-25 kV air
    Package0201 (0603 metric)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1241

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1241. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 1 A the clamp sits at 15.8 V, or 1.32 times the 12 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 60 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    8.5 pF per line is 18.7 ohms of reactance at 1 GHz and 187 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 12 V the part draws at most 1 uA, which is 12 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    Board Layout

    Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.