| Parameter | Value |
|---|---|
| Orderable part number | UP0.4C-150-R |
| OCL (open circuit inductance) | 14.5 uH ±20% |
| Irms (40 °C rise, no core loss) | 0.95 A |
| Isat (peak, rolloff per data sheet) | 0.94 A |
| DCR typical @ +20 °C | 250 mOhm |
| Package | 6.6 x 4.45 mm, 2.92 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4107 |

Drawing reproduced from Eaton Technical Data 4107: outline views
with rated mm dimensions, pad layout and marking.
The construction is one piece – drum, winding, terminations – which is why the family reaches 1000 uH in a package a few millimetres across while staying a surface-mount part. Values below 1 uH and above 500 uH sit in the same body size.
Copper loss at the 0.95 A rating is about 0.226 W with the typical DCR of 250 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 6.41 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
Within the UP0.4C family this is value 8 of 15, in a range from 1.16 to 102 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
Why does the inductance fall so gradually with current?
The drum has a distributed air gap along its length, so the core saturates progressively instead of all at once. That soft knee is why drum core parts stay usable slightly beyond the quoted saturation point.
Is the saturation current defined at 20 % or 30 % rolloff?
It varies by data sheet. The rolloff point is stated in the note under the table of each document; the number on this page is the one printed for this part, not a normalised figure.
How far does the field reach?
The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.