| Parameter | Value |
|---|---|
| Orderable part number | UP1B-150-R |
| Rated inductance | 15 uH ±20% |
| OCL (open circuit inductance) | 16 uH ±20% |
| Irms (40 °C rise, no core loss) | 1.2 A |
| Isat (peak, rolloff per data sheet) | 1.5 A |
| DCR typical @ +20 °C | 175 mOhm |
| Package | Four body sizes in this data sheet – see drawing |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data DS4308 |

Drawing reproduced from Eaton Technical Data DS4308: outline views
with rated mm dimensions, pad layout and marking.
This is a drum core choke chosen for DC-DC converters, filters and bias supplies where the board has room and the field is not the limiting factor. Irms is the thermal limit, Isat the magnetic one, and on the higher values the core saturates long before the winding overheats.
Copper loss at the 1.2 A rating is about 0.252 W with the typical DCR of 175 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 16.9 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
Within the UP1B family this is value 9 of 17, in a range from 0.47 to 330 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
Why is DCR quoted in ohms on some of these data sheets?
Because the values are large: a 1000 uH part can be several ohms. The table on this page converts the figure to milliohm so it can be compared directly with the rest of the family.
Can the part be used in a buck converter?
Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.
Can the part be used in a buck converter?
Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd