End of life: Eaton marks the UP2C series discontinued effective 30 November 2017 with no direct replacement; the data sheet points to UP2UC as the alternate. Not for new designs.
| Parameter | Value |
|---|---|
| Orderable part number | UP2C-151-R |
| Rated inductance | 150 uH ±20% |
| OCL (open circuit inductance) | 142 uH ±20% |
| Irms (40 °C rise, no core loss) | 1.04 A |
| Isat (peak, rolloff per data sheet) | 1.02 A |
| DCR typical @ +20 °C | 351 mOhm |
| Volt-time rating | 81.2 V-us |
| Package | 12.9 x 9.4 mm, 5.2 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4111 |

Drawing reproduced from Eaton Technical Data 4111: outline views
with rated mm dimensions, pad layout and marking.
This is a drum core choke chosen for DC-DC converters, filters and bias supplies where the board has room and the field is not the limiting factor. Irms is the thermal limit, Isat the magnetic one, and on the higher values the core saturates long before the winding overheats.
Copper loss at the 1.04 A rating is about 0.38 W with the typical DCR of 351 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 78 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
The 81.2 V-us volt-time rating sets the maximum flux excursion per switching cycle; at 100 kHz that is 8120 V of applied voltage for a full period.
Within the UP2C family this is value 15 of 20, in a range from 0.47 to 1000 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
Why is DCR quoted in ohms on some of these data sheets?
Because the values are large: a 1000 uH part can be several ohms. The table on this page converts the figure to milliohm so it can be compared directly with the rest of the family.
Why is DCR quoted in ohms on some of these data sheets?
Because the values are large: a 1000 uH part can be several ohms. The table on this page converts the figure to milliohm so it can be compared directly with the rest of the family.
How far does the field reach?
The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd