End of life: Eaton marks the UP2C series discontinued effective 30 November 2017 with no direct replacement; the data sheet points to UP2UC as the alternate. Not for new designs.
| Parameter | Value |
|---|---|
| Orderable part number | UP2C-331-R |
| Rated inductance | 330 uH ±20% |
| OCL (open circuit inductance) | 318 uH ±20% |
| Irms (40 °C rise, no core loss) | 0.67 A |
| Isat (peak, rolloff per data sheet) | 0.7 A |
| DCR typical @ +20 °C | 824 mOhm |
| Volt-time rating | 120 V-us |
| Package | 12.9 x 9.4 mm, 5.2 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4111 |

Drawing reproduced from Eaton Technical Data 4111: outline views
with rated mm dimensions, pad layout and marking.
A UNI-PAC drum core inductor is a wound coil on a ferrite drum with the winding brought out to two solder pads. There is no shield, so the field leaves the part along the drum axis. That is the trade: the most inductance per millimetre and per cent, paid for with a radiated field.
Copper loss at the 0.67 A rating is about 0.37 W with the typical DCR of 824 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 80.8 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
The 120 V-us volt-time rating sets the maximum flux excursion per switching cycle; at 100 kHz that is 12000 V of applied voltage for a full period.
Within the UP2C family this is value 17 of 20, in a range from 0.47 to 1000 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
Why does the inductance fall so gradually with current?
The drum has a distributed air gap along its length, so the core saturates progressively instead of all at once. That soft knee is why drum core parts stay usable slightly beyond the quoted saturation point.
How far does the field reach?
The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.
Is the saturation current defined at 20 % or 30 % rolloff?
It varies by data sheet. The rolloff point is stated in the note under the table of each document; the number on this page is the one printed for this part, not a normalised figure.