End of life: Eaton marks the UP2C series discontinued effective 30 November 2017 with no direct replacement; the data sheet points to UP2UC as the alternate. Not for new designs.
| Parameter | Value |
|---|---|
| Orderable part number | UP2C-470-R |
| Rated inductance | 47 uH ±20% |
| OCL (open circuit inductance) | 47.9 uH ±20% |
| Irms (40 °C rise, no core loss) | 1.77 A |
| Isat (peak, rolloff per data sheet) | 1.83 A |
| DCR typical @ +20 °C | 118 mOhm |
| Volt-time rating | 45.4 V-us |
| Package | 12.9 x 9.4 mm, 5.2 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4111 |

Drawing reproduced from Eaton Technical Data 4111: outline views
with rated mm dimensions, pad layout and marking.
The construction is one piece – drum, winding, terminations – which is why the family reaches 1000 uH in a package a few millimetres across while staying a surface-mount part. Values below 1 uH and above 500 uH sit in the same body size.
Copper loss at the 1.77 A rating is about 0.371 W with the typical DCR of 118 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 78.7 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
The 45.4 V-us volt-time rating sets the maximum flux excursion per switching cycle; at 100 kHz that is 4540 V of applied voltage for a full period.
Within the UP2C family this is value 12 of 20, in a range from 0.47 to 1000 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
How far does the field reach?
The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.
Why does the inductance fall so gradually with current?
The drum has a distributed air gap along its length, so the core saturates progressively instead of all at once. That soft knee is why drum core parts stay usable slightly beyond the quoted saturation point.
Why is DCR quoted in ohms on some of these data sheets?
Because the values are large: a 1000 uH part can be several ohms. The table on this page converts the figure to milliohm so it can be compared directly with the rest of the family.