Eaton UP2C-680-R 68 uH Inductor, DCR 152 mOhm
Eaton UP2C-680-R 68 uH Inductor, DCR 152 mOhm

Eaton UP2C-680-R 68 uH Inductor, DCR 152 mOhm

Share
UP2C-680-R at a glance (discontinued): UNI-PAC drum core power inductor, 68 uH ±20%, 1.57 A Irms, Isat 1.53 A, DCR 152 mOhm.
    • Product Details
    • Download

    Eaton UP2C-680-R 68 uH Inductor, DCR 152 mOhm

    UP2C-680-R at a glance (discontinued): UNI-PAC drum core power inductor, 68 uH ±20%, 1.57 A Irms, Isat 1.53 A, DCR 152 mOhm.

    End of life: Eaton marks the UP2C series discontinued effective 30 November 2017 with no direct replacement; the data sheet points to UP2UC as the alternate. Not for new designs.

    Electrical Specifications

    ParameterValue
    Orderable part numberUP2C-680-R
    Rated inductance68 uH ±20%
    OCL (open circuit inductance)65 uH ±20%
    Irms (40 °C rise, no core loss)1.57 A
    Isat (peak, rolloff per data sheet)1.53 A
    DCR typical @ +20 °C152 mOhm
    Volt-time rating54.3 V-us
    Package12.9 x 9.4 mm, 5.2 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4111

    Dimensions and Pad Layout

    UP2C-680-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4111: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A UNI-PAC drum core inductor is a wound coil on a ferrite drum with the winding brought out to two solder pads. There is no shield, so the field leaves the part along the drum axis. That is the trade: the most inductance per millimetre and per cent, paid for with a radiated field.

    Copper loss at the 1.57 A rating is about 0.374 W with the typical DCR of 152 mOhm. Ripple current adds to that through the AC resistance.

    The core holds about 79.6 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.

    The 54.3 V-us volt-time rating sets the maximum flux excursion per switching cycle; at 100 kHz that is 5430 V of applied voltage for a full period.

    Within the UP2C family this is value 13 of 20, in a range from 0.47 to 1000 uH.

    Series Positioning

    The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.

    • Unshielded. Do not route traces or vias underneath the body, and keep the drum axis away from sensitive nodes and from any magnetic sensor.
    • Typical applications: desktop computer; workstations/servers; dvd players; portable power devices; base stations.
    • Design note: on the high-value rows the core saturates well before the winding reaches its thermal limit. Size against Isat for those values.

    Frequently Asked Questions

    Is the saturation current defined at 20 % or 30 % rolloff?
    It varies by data sheet. The rolloff point is stated in the note under the table of each document; the number on this page is the one printed for this part, not a normalised figure.

    Is the saturation current defined at 20 % or 30 % rolloff?
    It varies by data sheet. The rolloff point is stated in the note under the table of each document; the number on this page is the one printed for this part, not a normalised figure.

    Can the part be used in a buck converter?
    Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.