| Parameter | Value |
|---|---|
| Orderable part number | UP2UC-151-R |
| OCL (open circuit inductance) | 150 uH ±20% |
| Irms (40 °C rise, no core loss) | 1 A |
| Isat (peak, rolloff per data sheet) | 1 A |
| DCR typical @ +20 °C | 347 mOhm |
| DCR maximum @ +20 °C | 400 mOhm |
| SRF typical | 6 MHz |
| K-factor | 15.8 |
| Package | 12.7 x 9.3 mm, 5.21 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4369 |

Drawing reproduced from Eaton Technical Data 4369: outline views
with rated mm dimensions, pad layout and marking.
The construction is one piece – drum, winding, terminations – which is why the family reaches 1000 uH in a package a few millimetres across while staying a surface-mount part. Values below 1 uH and above 500 uH sit in the same body size.
Copper loss at the 1 A rating is about 0.347 W with the typical DCR of 347 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 75 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
Within the UP2UC family this is value 14 of 19, in a range from 1 to 1000 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
Why does the inductance fall so gradually with current?
The drum has a distributed air gap along its length, so the core saturates progressively instead of all at once. That soft knee is why drum core parts stay usable slightly beyond the quoted saturation point.
Can the part be used in a buck converter?
Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.
Can the part be used in a buck converter?
Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd