Eaton UP2UC-3R3-R 3.3 uH Inductor, DCR 9.9 mOhm
Eaton UP2UC-3R3-R 3.3 uH Inductor, DCR 9.9 mOhm

Eaton UP2UC-3R3-R 3.3 uH Inductor, DCR 9.9 mOhm

Share
UP2UC-3R3-R: UNI-PAC drum core power inductor, 3.3 uH ±20%, 5.4 A Irms, Isat 6.4 A, DCR 9.9 mOhm.
    • Product Details
    • Download

    Eaton UP2UC-3R3-R 3.3 uH Inductor, DCR 9.9 mOhm

    UP2UC-3R3-R at a glance: UNI-PAC drum core power inductor, 3.3 uH ±20%, 5.4 A Irms, Isat 6.4 A, DCR 9.9 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberUP2UC-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    Irms (40 °C rise, no core loss)5.4 A
    Isat (peak, rolloff per data sheet)6.4 A
    DCR typical @ +20 °C9.9 mOhm
    DCR maximum @ +20 °C15 mOhm
    SRF typical65 MHz
    K-factor114
    Package12.7 x 9.3 mm, 5.21 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4369

    Mechanical Dimensions & Pad Layout

    UP2UC-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4369: outline views
    with rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    Drum core parts are the traditional answer to “I need a few microhenry at a few amps and I do not want to pay for a shielded part”. The open magnetic path gives a soft saturation curve, so the inductance falls away gradually rather than collapsing at the knee.

    Copper loss at the 5.4 A rating is about 0.289 W with the typical DCR of 9.9 mOhm. Ripple current adds to that through the AC resistance.

    The core holds about 67.6 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.

    Within the UP2UC family this is value 4 of 19, in a range from 1 to 1000 uH.

    Positioning in the Range

    The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.

    • Unshielded. Do not route traces or vias underneath the body, and keep the drum axis away from sensitive nodes and from any magnetic sensor.
    • Typical applications: desktop computer; workstations/servers; dvd players; portable power devices; base stations.
    • Design note: on the high-value rows the core saturates well before the winding reaches its thermal limit. Size against Isat for those values.

    Frequently Asked Questions

    How far does the field reach?
    The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.

    Can the part be used in a buck converter?
    Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.

    Why is DCR quoted in ohms on some of these data sheets?
    Because the values are large: a 1000 uH part can be several ohms. The table on this page converts the figure to milliohm so it can be compared directly with the rest of the family.