| Parameter | Value |
|---|---|
| Orderable part number | UP5-102-R |
| OCL (open circuit inductance) | 1000 uH ±20% |
| Irms (40 °C rise, no core loss) | 0.56 A |
| Isat (peak, rolloff per data sheet) | 1 A |
| DCR typical @ +20 °C | 1800 mOhm |
| SRF typical | 2 MHz |
| K-factor | 2.54 |
| Package | 18.54 x 15.24 mm, 7.11 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4409 |

Drawing reproduced from Eaton Technical Data 4409: outline views
with rated mm dimensions, pad layout and marking.
This is a drum core choke chosen for DC-DC converters, filters and bias supplies where the board has room and the field is not the limiting factor. Irms is the thermal limit, Isat the magnetic one, and on the higher values the core saturates long before the winding overheats.
Copper loss at the 0.56 A rating is about 0.564 W with the typical DCR of 1800 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 500 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
Within the UP5 family this is value 18 of 18, in a range from 1 to 1000 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
How far does the field reach?
The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.
Can the part be used in a buck converter?
Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.
Can the part be used in a buck converter?
Yes, within its current and frequency range. Check the core-loss curve at the switching frequency and the ripple before treating the DC rating as the limit.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd