Eaton VP2-0116-R Multi-Winding Transformer 5.7 uH
Eaton VP2-0116-R Multi-Winding Transformer 5.7 uH

Eaton VP2-0116-R Multi-Winding Transformer 5.7 uH

Share
VP2-0116-R: configurable six-winding inductor transformer, 5.7 uH.
    • Product Details
    • Download

    Eaton VP2-0116-R Multi-Winding Transformer 5.7 uH

    VP2-0116-R at a glance: configurable six-winding inductor transformer, 5.7 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberVP2-0116-R
    Inductance, base winding5.7 uH
    Isat base1.41 A
    Irms base1.26 A
    R base maximum90 mOhm
    Volt-time33.7 V-us
    Peak energy3.94 uJ
    Leakage inductance0.083 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A six-winding configurable inductor: the windings can be paralleled for current, series-connected for inductance, or used as a multi-winding transformer. One part covers a wide design space, which is why the data sheet gives base ratings and a table of configurations rather than a single row.

    Within the VP2 family this is item 3 of 4 in the Eaton catalogue.

    Series Positioning

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Shenzhen Gaorunxin Technology Co., Ltd