Eaton VP2A1V-0116-R Multi-Winding Transformer 5.7 uH
Eaton VP2A1V-0116-R Multi-Winding Transformer 5.7 uH

Eaton VP2A1V-0116-R Multi-Winding Transformer 5.7 uH

Share
VP2A1V-0116-R: configurable six-winding inductor transformer, 5.7 uH.
    • Product Details
    • Download

    Eaton VP2A1V-0116-R Multi-Winding Transformer 5.7 uH

    VP2A1V-0116-R at a glance: configurable six-winding inductor transformer, 5.7 uH.

    Ratings at a Glance

    ParameterValue
    Orderable part numberVP2A1V-0116-R
    Inductance, base winding5.7 uH
    Isat base1.6 A
    Irms base1.26 A
    R base maximum90 mOhm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1210

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1210; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A six-winding configurable inductor: the windings can be paralleled for current, series-connected for inductance, or used as a multi-winding transformer. One part covers a wide design space, which is why the data sheet gives base ratings and a table of configurations rather than a single row.

    Within the VP2A1V family this is item 3 of 4 in the Eaton catalogue.

    Series Positioning

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: motion controls; robotics; iot, 5g,; amrs (meter readers); dc-dc converters.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message