Eaton VP4A1V-0047-R Multi-Winding Transformer 3.8 uH
Eaton VP4A1V-0047-R Multi-Winding Transformer 3.8 uH

Eaton VP4A1V-0047-R Multi-Winding Transformer 3.8 uH

Share
VP4A1V-0047-R: configurable six-winding inductor transformer, 3.8 uH.
    • Product Details
    • Download

    Eaton VP4A1V-0047-R Multi-Winding Transformer 3.8 uH

    VP4A1V-0047-R at a glance: configurable six-winding inductor transformer, 3.8 uH.

    Key Specifications

    ParameterValue
    Orderable part numberVP4A1V-0047-R
    Inductance, base winding3.8 uH
    Isat base3.66 A
    Irms base1.7 A
    R base maximum57 mOhm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1210

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1210; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    The ratings on this page are for the base winding with all others open or paralleled as noted. Any other connection changes the effective inductance and current, and the table of configurations is the place to look.

    Within the VP4A1V family this is item 1 of 4 in the Eaton catalogue.

    Series Positioning

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: motion controls; robotics; iot, 5g,; amrs (meter readers); dc-dc converters.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    Shenzhen Gaorunxin Technology Co., Ltd