Eaton VP4A1V-0060-R Configurable Power Inductor
Eaton VP4A1V-0060-R Configurable Power Inductor

Eaton VP4A1V-0060-R Configurable Power Inductor

Share
VP4A1V-0060-R: configurable six-winding inductor transformer, 4.9 uH.
    • Product Details
    • Download

    Eaton VP4A1V-0060-R Configurable Power Inductor

    VP4A1V-0060-R at a glance: configurable six-winding inductor transformer, 4.9 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberVP4A1V-0060-R
    Inductance, base winding4.9 uH
    Isat base2.83 A
    Irms base1.7 A
    R base maximum57 mOhm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1210

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1210; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    Configurable magnetics trade a little efficiency for flexibility: more windings in the same window means thinner wire, so the DCR is higher than a dedicated part of the same inductance.

    Within the VP4A1V family this is item 2 of 4 in the Eaton catalogue.

    Positioning in the Range

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: motion controls; robotics; iot, 5g,; amrs (meter readers); dc-dc converters.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    Why is the DCR higher than a dedicated inductor?
    Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.

    Are the ratings per winding or total?
    The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.