    VPH3-0055-R at a glance: configurable six-winding inductor transformer, 9.3 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberVPH3-0055-R
    Inductance, base winding9.3 uH
    Isat base1.02 A
    Irms base0.97 A
    R base maximum140 mOhm
    Volt-time39.8 V-us
    Peak energy3.38 uJ
    Leakage inductance0.125 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    Versa-Pac parts are built for prototyping and for designs that need several different magnetics on one board: the same footprint can be a 10 uH inductor at full current or a 1:1 transformer, depending on how the six windings are wired.

    Within the VPH3 family this is item 2 of 4 in the Eaton catalogue.

    What This Family Is For

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    Why is the DCR higher than a dedicated inductor?
    Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.

    Why is the DCR higher than a dedicated inductor?
    Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.